Skip to content
Online Payment Digital Catalogue
Online Payment Service Request
Repair and Maintenance

Servo Drive Repair

The assessment covers the power module, power supply, control electronics and an appropriate operational test. The terms drive and inverter are used according to device category; not every inverter is considered a servo drive.

Servo drive on a test bench; power and control connections visible. Real laboratory / field photo
01

Service overview

The assessment covers the power module, power supply, control electronics and an appropriate operational test. The terms drive and inverter are used according to device category; not every inverter is considered a servo drive.

Parameters and backup: whether a backup can be taken depends on the condition of the device and on access; no guarantee is given that data will not be lost. If possible, back up your existing parameters before shipping.

02

Which symptoms call for an assessment?

  • Alarm codeA recurring error on the display; the code and the conditions under which it occurs matter.
  • No power-upPower is present, but the drive does not start up.
  • Frequent trippingCuts out at a certain load or temperature.
  • Motor does not startA command is given, but there is no movement.

A symptom is not a diagnosis; the cause becomes clear during laboratory diagnosis.

03

Work performed

The work performed depends on the device design and the diagnosis.
AreaDescription
Power stageIGBT / power module and gate driver circuits.
Power supplyInput and internal supply stages.
Control electronicsControl board, communication and feedback interface.
Operational testTesting under suitable conditions, depending on equipment compatibility.
04

Analysis and testing approach

The wording “tested under load” is used according to device compatibility and the test actually performed; it is not assumed that every drive is tested in the same way. Alarm examples have no universal meaning without the brand and model.

The motor – drive – cable trio. The symptom may originate in the motor: Servo Motor Repair.
05

Quotation, approval and delivery process

  1. Registration

    We record the device details and symptoms and send you a reference number.

  2. Analysis

    The fault is diagnosed in the laboratory, so it is clear what has failed.

  3. Quotation and approval

    Scope and price are confirmed in writing; nothing is done without your approval.

  4. Repair

    The repair is carried out within the approved scope; you are informed of any deviation.

  5. Testing and delivery

    The device is tested under suitable conditions and returned with a short technical summary.

06

Preparing for shipment

Provide a photo of the alarm, the full model and the conditions under which the fault occurs. The field is plain text so that you can easily type the alarm code on a mobile device.

07

Frequently asked

08

Related services and work

View the related album
CallReport a Drive Fault
WhatsAppSend photos and device details Phone+90 545 729 49 11